x
Send Your Inquiry Today
Quick Quote
  • 1500 KVA Dry-type Transformers-6.6/0.55 KV | South Africa 2025
  • 1500 KVA Dry-type Transformers-6.6/0.55 KV | South Africa 2025 manufacturer
  • 1500 KVA Dry-type Transformers-6.6/0.55 KV | South Africa 2025 after-sale service
  • 1500 KVA Dry-type Transformers-6.6/0.55 KV | South Africa 2025 suppliers
  • 1500 KVA Dry-type Transformers-6.6/0.55 KV | South Africa 2025 factory
  • 1500 KVA Dry-type Transformers-6.6/0.55 KV | South Africa 2025 best
  • 1500 KVA Dry-type Transformers-6.6/0.55 KV | South Africa 2025 high quality
  • 1500 KVA Dry-type Transformers-6.6/0.55 KV | South Africa 2025 price
  • 1500 KVA Dry-type Transformers-6.6/0.55 KV | South Africa 2025
  • 1500 KVA Dry-type Transformers-6.6/0.55 KV | South Africa 2025 manufacturer
  • 1500 KVA Dry-type Transformers-6.6/0.55 KV | South Africa 2025 after-sale service
  • 1500 KVA Dry-type Transformers-6.6/0.55 KV | South Africa 2025 suppliers
  • 1500 KVA Dry-type Transformers-6.6/0.55 KV | South Africa 2025 factory
  • 1500 KVA Dry-type Transformers-6.6/0.55 KV | South Africa 2025 best
  • 1500 KVA Dry-type Transformers-6.6/0.55 KV | South Africa 2025 high quality
  • 1500 KVA Dry-type Transformers-6.6/0.55 KV | South Africa 2025 price

1500 KVA Dry-type Transformers-6.6/0.55 KV | South Africa 2025

Country: South Africa 2025
Capacity: 1500 kVA
Voltage: 6.6/0.55 kV
Feature: with fans

dry-type transformers

Smart Distribution, Worry-Free Operation - Trust Cast Coil Dry Type Transformer in modern power systems.

01 General

1.1 Project Description

1500kVA cast coil dry-type transformers was delivered to South Africa in 2025. The rated power of the transformer is 1500 kVA with AN/AF cooling. The primary voltage is 6.6 kV with ±2*2.5% tapping range (NLTC), the secondary voltage is 0.55 kV, they formed a vector group of Dyn11.

Our Cast Coil dry-type transformers represents the pinnacle of safety, reliability, and efficiency in modern power distribution. Engineered with epoxy resin-encapsulated high-voltage coils, it is completely oil-free, making it the ideal, maintenance-lean choice for indoor installations where fire safety and environmental protection are paramount.

A key feature of this transformer is its integrated intelligent fan cooling system (WTB). This system actively monitors the operating temperature and automatically activates high-efficiency axial fans when needed. This forced-air cooling significantly boosts the transformer’s thermal capacity and increases its short-term overload capability, ensuring stable and continuous operation even under demanding or fluctuating load conditions.

Designed for versatile global applications, this unit operates with a standard power supply voltage of 220V. Its compact and robust construction, combined with the cast resin coil technology, provides exceptional resistance to moisture, dust, and corrosive environments. This makes it perfectly suited for a wide range of critical settings, including:

  • Commercial & Public Buildings: Shopping malls, hospitals, airports, and high-rise complexes.
  • Industrial Facilities: Manufacturing plants, production lines, and chemical processing units.
  • Infrastructure & Special Projects: Subway systems, tunnels, ships, and offshore platforms.
  • Renewable Energy Integration: Wind and solar power generation systems.

1.2 Technical Specification

1500 kVA cast coil dry-type transformers specification and data sheet

Delivered toSouth Africa
Year2025
Typedry type transformer
Core materialGrain oriented silicon steel sheet
StandardIEC60076
Rated Power1500kVA
Frequency50HZ
Vector groupDyn11
Phase3
Cooling TypeAN/AF
Primary Voltage6.6kV
Secondary Voltage0.55kV
Winding MaterialCopper
Impedance6%
Tap ChangerNLTC
Tapping Range±2*2.5%@primary side
No Load Loss2.45KW
On Load Loss11.73KW
Basic impulse lighting withstand voltage primary side (BIL)60kV
Power Frequency withstand voltage-primary side20kV
Power Frequency withstand voltage-secondary side3kV
Winding temperature rise@ rated service condition100K
Insulation levelF

1.3 Drawings

1500 kVA cast resin dry-type transformers diagram drawing and size.

dry-type transformers diagram

02 Manufacturing

2.1 Winding

The heart of the cast coil dry-type transformers is its meticulously engineered coil system, utilizing high-conductivity copper windings that are fully encapsulated through a vacuum casting process with premium-grade epoxy resin. This advanced encapsulation forms a seamless, solid insulation body around the copper conductors, creating a monolithic, mechanically robust, and void-free structure. The epoxy resin not only provides exceptional dielectric strength and partial discharge resistance but also ensures superior thermal conductivity, effectively dissipating heat from the windings. This construction results in a coil that is highly resistant to moisture, dust, chemicals, and harsh environmental conditions, guaranteeing long-term stability, safety, and maintenance-free operation.dry-type transformers winding

2.2 Temperature Controller

Temperature ControllerThe temperature controller for cast coil dry type transformers features built-in PT100 probes in the three-phase windings to monitor real-time winding temperatures and display them cyclically on a digital screen. It offers circuit open and self-check fault alarms, plus three-stage temperature responses: automatic fan activation at the first stage, a high-temperature alarm at the second, and an overtemperature trip at the third. Additional functions include manual/auto fan control, timed fan start/stop, historical data logging and output, and it operates on a 220V power supply.

2.3 Fans

The cooling fans for the cast coil dry type transformer are mounted at the bottom of the unit. Their start/stop cycles are automatically regulated by the transformer’s temperature controller, which activates them based on real-time winding temperature data to boost heat dissipation. Operating on a 220V power supply and provided as one complete lot, these fans play a key role in maintaining optimal thermal conditions, preventing overheating, and ensuring the reliable, continuous performance of the transformer.fans

2.4 Nameplate

dry type transformer nameplateThe transformer’s nameplate provides its essential technical identity. It permanently displays the manufacturer, model, serial number, and kVA rating, along with core electrical data like voltages, frequency, vector group, and impedance. Required safety warnings and certification marks (e.g., IEC) are also included, serving as a vital reference for installation, operation, and compliance throughout its service life.

03 Testing

The Measurement of Short-Circuit Impedance and Load Loss is a critical routine test performed by short-circuiting the secondary windings and applying a reduced voltage at the rated frequency to the primary side. This test precisely determines the transformer’s equivalent impedance, a key parameter for calculating voltage regulation and prospective fault currents. Simultaneously, it measures the total load loss (primarily copper losses due to winding resistance), which is essential for verifying design efficiency, ensuring compliance with specifications, and predicting operational performance and temperature rise under load.

04 Packing and Shipping

4.1 Packing

The packaging of cast coil dry type transformers uses moisture-proof film wrapping combined with wooden pallets or sealed wooden cases, with internal shock-absorbing padding to mitigate transit impacts. Clear shipping marks, handling warnings, and product specifications are visibly labeled on the exterior. This packaging adheres to international transportation standards, ensuring the transformer remains protected and intact during land or sea shipping.packaging of cast coil dry type transformers

4.2 Shipping

sea freight under CIF termsThe cast coil dry type transformer is transported via sea freight under CIF (Cost, Insurance and Freight) terms to the Port of Durban, where the seller bears responsibility for covering ocean freight, cargo insurance, and delivery costs to the destination port. Secured in moisture-proof, shock-absorbent packaging compliant with international maritime standards, the transformer is protected against moisture, impact, and transit damage, ensuring it arrives intact and ready for onward handling upon arrival at Durban port.

05 Site And Summary

SCOTECH cast coil dry type transformers feature cast insulation, safety and maintenance-free operation, ideal for industrial, commercial and new energy supporting scenarios. Manufactured in strict compliance with IEC standards, they deliver stable and reliable performance for worry-free power supply. We look forward to partnering with you for efficient power distribution solutions.

IEC standards dry transformer

Let's Discuss Your Needs and Find the Right Solution!

Lorem ipsum dolor sit amet, sea ea saepe intellegam, purto utinam consetetur ex duo, an recteque liberavisse signiferumque qui. An sea duis dissentiunt.
Scroll to Top