  • 750 kva 13.2 kv to 0.48 kv loop feed pad mounted transformer door open internal view
  • 750 kva 13.2 kv to 0.48 kv loop feed pad mounted transformer front view
  • 750 kva 13.2 kv to 0.48 kv loop feed pad mounted transformer right front 45deg view
  • 750 kva 13.2 kv to 0.48 kv loop feed pad mounted transformer rear view
  • 750 kva 13.2 kv to 0.48 kv loop feed pad mounted transformer left rear 45deg view
  • 750 kva 13.2 kv to 0.48 kv loop feed pad mounted transformer left side view
  • 750 kva 13.2 kv to 0.48 kv loop feed pad mounted transformer door open internal view
  • 750 kva 13.2 kv to 0.48 kv loop feed pad mounted transformer front view
  • 750 kva 13.2 kv to 0.48 kv loop feed pad mounted transformer right front 45deg view
  • 750 kva 13.2 kv to 0.48 kv loop feed pad mounted transformer rear view
  • 750 kva 13.2 kv to 0.48 kv loop feed pad mounted transformer left rear 45deg view
  • 750 kva 13.2 kv to 0.48 kv loop feed pad mounted transformer left side view

750 KVA Pad Mounted Transformer Loop Feed-13.2/0.48 KV | USA 2024

Delivery Country: America 2024
Capacity: 750kVA
Voltage: 13.2/0.48kV
Feature: Three-phase three-limb

750 kva 13.2 kv to 0.48 kv loop feed pad mounted transformer

Scotech pad-mounted transformers with loop feed deliver safe, reliable power

01 General

1.1 Project Description

This 750kVA three phase pad mounted transformer was delivered to America in 2024. It is made under IEEE Std C57.12.34-2022 and meets the DOE 2016 energy efficiency standard. The efficiency is 99.4%. It has a loop feed and dead-front design for safe and easy use in industrial and commercial areas. The rated power is 750kVA, with a primary voltage of 13.2 kV and a secondary voltage of 0.48 kV. The transformer is UL listed, meeting U.S. safety standards.

The impedance is 5.75%. The no-load loss is 1.05kW. The load loss is 5.4kW. These low losses save energy and improve performance. The tap changer is no-load type (NLTC). It has a ±2×2.5% range to adjust the voltage.

Aluminum windings are light, strong, and good for heat transfer. It keeps the transformer cool and stable under load. The ONAN cooling system uses natural oil and air flow to control temperature.

The tank is made of mild steel and coated with anti-corrosion paint. It is strong and leak-proof. The dead-front structure keeps users safe by covering live parts. The loop feed system allows continuous operation when one side is under maintenance, which improves reliability in power networks.
This transformer is used in Industrial facilities and utility distribution systems. It is also suitable for commercial centers, data facilities, and outdoor substations. It provides stable and efficient power where reliability and safety are important.

 

1.2 Technical Specification

750kVA three phase pad mounted transformer specification and data sheet

Delivered toAmerica
Year2024
TypeThree phase pad mount transformer
StandardIEEE Std C57.12.34-2022
Rated Power750KVA
Frequency60HZ
FeedLoop
FrontDead
Phasethree
Cooling TypeONAN
Liquid insulantMineral Oil
Primary Voltage13.2 kV
Secondary Voltage0.48 kV
Vector GroupDyn1
Winding MaterialAluminum
Impedance5.75%
Efficiency and Losses StandardDOE 2016 , 99.4%
Tap ChangerNLTC
Tapping Range±2*2.5%
No Load Loss1.05 kV
On Load Loss5.4 kV
AccessoriesStandard Configuration

1.3 Drawings

750kVA three phase pad mounted transformer drawing and nameplate

02 Manufacturing

2.1 Core

This Pad Mounted Transformer Loop Feed is engineered in full compliance with DOE 2016 efficiency standards, achieving 99.4% energy efficiency. The core uses high-grade grain-oriented silicon steel (GOES) with step-lap joints to reduce magnetic flux distortion, significantly lowering no-load loss (1.05 kW) and improving overall energy performance and noise control.

2.2 Winding

The 750 kVA pad mounted transformer loop feed is designed using high-purity aluminum conductors optimized for low resistance and reduced load losses (5.4 kW). Reinforced interlayer insulation enhances dielectric strength and short-circuit withstand capability, ensuring stable performance under continuous industrial and utility load conditions.

2.3 Tank

The Pad Mounted Transformer Loop Feed tank is constructed from high-strength mild steel with fully sealed bolted cover design. Anti-corrosion coating ensures long service life in harsh environments. Structural optimization reduces stray losses and supports stable magnetic balance, improving overall operational efficiency and mechanical durability.750 kva 13.2 kv to 0.48 kv loop feed pad mounted transformer oil tank

2.4 Integrated Protection

750 kva 13.2 kv to 0.48 kv loop feed pad mounted transformer monitoring system

Equipped with HV/LV bushings, LBOR switch, bayonet fuse with CLFs, radiators, pressure relief device, liquid level gauge, vacuum pressure gauge, and dial thermometer. These components ensure safe operation, real-time condition monitoring, and enhanced protection, fully supporting DOE-compliant reliable performance.

2.5 Final assembly

Core and coil assemblies are precisely aligned and vacuum oil-filled to ensure insulation integrity. Comprehensive factory testing includes ratio, resistance, losses, insulation, dielectric, and leak tests. Final inspection confirms nameplate accuracy and wiring compliance, ensuring every Pad Mounted Transformer Loop Feed meets DOE 2016 efficiency and reliability standards.

750 kva 13.2 kv to 0.48 kv loop feed pad mounted transformer assembly

03 Testing

Testing Standard

IEEE C57.12.00-2021IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers
IEEE Std C57.12.34-2022IEEE Standard Requirements for Pad-Mounted, Compartmental-Type, Self-

Cooled, Three-Phase Distribution Transformers, 10 MVA and Smaller; High-Voltage, 34.5 kV Nominal System Voltage and Below; Low-Voltage, 15 kV Nominal System Voltage and Below

IEEE C57.12.90-2021IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformer

Routine Test

1. Resistance Measurements
2. Ratio Tests
3. Phase-relation Test
4. No Load Losses and No Load Current
5. Load Losses Impedance Voltage and Efficiency
6. Applied Voltage Test
7. Induced Voltage Withstand Test
8. Leak Testing with Pressure for Liquid Immersed Transformers
9. Insulation Resistance Measurement
10. Oil Dielectric Test

04 Packing and Shipping

05 Site And Summary

750 kva 13.2 kv to 0.48 kv loop feed pad mounted transformer waiting for shippingThe Scotech 750kVA pad mounted transformer loop feed was delivered to America in 2024. Its loop feed and dead-front design provide safety, easy maintenance, and continuous operation.

The transformer uses a three-limb silicon steel core with low loss and low noise. Aluminum windings give strong performance, good heat transfer, and long service life. Standard and additional accessories include bushings, pressure relief valve, tap changer, bayonet fuse with CLFs, 2-position LBOR switch, liquid level gauge, pressure vacuum gauge, dial-type thermometer, and drain and sample valve.

The transformer is vacuum-filled with mineral oil and passes routine tests for resistance, ratio, phase relation, losses, voltage withstand, insulation, leak, and oil dielectric performance. Scotech transformers deliver reliable, energy-efficient, and cost-effective power for modern 3-phase distribution networks.