4390 KVA Transformer-24/0.63 KV | Jamaica 2025

Country: Jamaica 2025
Capacity: 4390 kVA
Voltage: 23.9GrdY/13.8-0.63D kV
Feature: C5M Anti-corrosion Grade

4390 kva transformer

Choose pad mounted transformers for efficient, compact energy distribution.

01 General

1.1 Project Description

4390 kVA three phase pad mounted transformer was delivered to Jamaica in 2025. The rated power of the pad mount transformer is 4390 kVA with ONAN cooling. The high voltage is 23.9GrdY/13.8 kV with ±2*2.5% tapping range (NLTC), the low voltage is 0.63D kV, they formed a vector group of YNd1.

Engineered for superior performance in modern electrical networks, our 4390 kva transformer delivers exceptional reliability and efficiency. This robust unit features a three-phase, three-limb core optimized for 50Hz operation, achieving an impressive 99.2% efficiency with a 7.5% impedance for stable grid performance. Filled with eco-friendly FR3 dielectric fluid, it enhances fire safety and operational longevity. Critical to its design are the integrated Grounding Shield and Isolation Screen Grounding Sleeve, which ensure maximum safety by effectively containing electromagnetic interference and protecting personnel. Housed in a resilient 304 stainless steel enclosure finished in a corrosion-resistant, C5M-grade white powder coat (RAL 9003), it is built to endure the most demanding environmental conditions.

With a robust operational capacity of 4330kVA at 45°C and 4075kVA at 50°C, this transformer stands as a secure, durable, and intelligent cornerstone for your power distribution infrastructure.

1.2 Technical Specification

4390 kva transformer specifications type and data sheet

Delivered toJamaica
Year2025
TypePad mounted transformer
StandardIEC 60076
Rated Power4390 kVA
Frequency50HZ
Phase3
FeedLoop
FrontDead
Cooling TypeKNAN
Primary Voltage23.9GrdY/13.8 kV
Secondary Voltage0.69 kV
Winding MaterialCopper
Vector GroupYNd1
Impedance7.5%
Efficiency99.2%
Tap ChangerNLTC
Tapping Range±2*2.5%
No Load Loss3.95 kW
On Load Loss28 kW

1.3 Drawings

4390 kva transformer diagram drawing and size.

02 Manufacturing

2.1 Core

Our three-limb core, crafted from premium silicon steel, is engineered for maximum energy savings and minimal noise. It directly delivers lower electricity bills and quiet operation, making it an ideal, neighbor-friendly choice for cost-effective and sustainable power distribution.4390 kva transformer core

2.2 Winding

4390 kva transformer copper winding with high efficiencyOur all-copper winding system combines HV foil and LV wire for maximum efficiency and heat resistance. This superior design ensures lower energy loss, enhanced short-circuit strength, and extended transformer life – delivering true value through reduced operating costs.

2.3 Tank

Our 304 stainless steel tank with C5M protection withstands harsh environments effortlessly. The durable white finish stays clean and corrosion-free for decades, eliminating maintenance costs and ensuring worry-proof operation in coastal or industrial areas.4390 kva transformer 304 stainless steel tank with C5M protection withstands harsh environments effortlessly

2.4 Final Assembly

4390 kva transformer final assembled providing decades of maintenance-free operationOur final assembly ensures perfect synergy between the high-efficiency core, all-copper windings, and stainless steel tank. This precision integration delivers guaranteed performance with lower lifetime costs, providing decades of maintenance-free operation.

03 Testing

Tailored to your core needs for reliability, efficiency, and quality transparency, our 4390 kva transformer undergoes comprehensive testing that goes beyond basic compliance. Following IEC standards, key tests include precise winding resistance checks (max unbalance rate 4.59%), low no-load loss (3.564kW), robust dielectric withstand, and 24-hour leak-proof verification. We stand out by delivering measurable excellence: 99.28% efficiency (exceeding the 99.2% minimum), consistent phase relation (YNd1). We offer clear, actionable test data and prompt inquiry support, giving you the confidence that your transformer is energy-efficient, durable, and backed by a manufacturer committed to your operational success.

No.Test ItemUnitAcceptance

Values

Measured ValuesConclusion
1Resistance Measurements%Maximum resistance unbalance rate4.59Pass
2Ratio Tests%The deviation of voltage ratio on the principal tapping: ≤0.5%

Connection symbol: YNd1

-0.05% ~ -0.03%Pass
3phase-relation tests/YNd1YNd1Pass
4No-load losses and excitation current/I0 :: provide measured value0.23%Pass
P0: provide measured value3.564kW
the tolerance for no load loss is +15%/
5Load losses impedance voltage and efficiency/t:75℃

the tolerance for impedance is ±10%

the tolerance for total load loss is +10%

/Pass
Z%: measured value7.06%
Pk: measured value28.162kW
Pt: measured value31.726kW
Efficiency not less than 99.2%99.28%
6Applied Voltage TestkVLV/: 10kV 60sNo collapse of the test voltage occursPass
7Induced Voltage Withstand TestkVApplied voltage (KV):2UrNo collapse of the test voltage occursPass
Duration(s):40
Frequency (HZ): 150
8Leakage TestkPaApplied pressure: 50kPANo leakage and no

Damage

Pass
Duration: 24h
9Insulation Resistance MeasurementGΩHV-LV to Ground1.87/
LV-HV to Ground1.15
HV&LV to Ground0.832

04 Packing and Shipping

4.1 Packing

We ship every unit in custom-built wooden crates, engineered for maximum protection during transit. This robust packaging ensures your transformer arrives on site in perfect, ready-to-install condition, eliminating the financial risks and project delays associated with transportation damage.4390 kva transformer wooden crates

4.2 Shipping

4390 kva transformer DDU transportWe expertly manage the entire DDU transport chain of your three-phase pad-mounted transformer to PAC Kingston Airport Ltd. (KIN). Our meticulous planning, from specialized wooden-crate packaging that exceeds industry standards to navigating KIN’s specific cargo protocols and 24/7 electronic customs, ensures your critical asset arrives safely and on schedule. This seamless, hassle-free delivery to your specified destination mitigates the risks of damage and project delays, providing you with absolute peace of mind.

05 Site And Summary

When your project’s success depends on unwavering power supply and on-schedule delivery, you need certainty in your equipment and your supplier. Our three-phase pad mounted transformers are engineered for exactly that-delivering unmatched reliability to keep your operations running. But our advantage goes further: it’s our commitment to your timeline. With rigorous pre-delivery testing and a streamlined global supply chain, we ensure your transformer arrives on site as promised, ready for a trouble-free installation. Don’t let operational risks or delays jeopardize your project. Choose the confidence that comes with our proven track record and specify the transformer trusted by utilities and industries worldwide.