x
Send Your Inquiry Today
Quick Quote
  • 1-1000 kva 34.5 kv to 0.48 kv three-phase five-column bess transformer side instrument box with grounding shield internal view with enclosure open
  • 2-1000 kva 34.5 kv to 0.48 kv three-phase five-column bess transformer side instrument box with grounding shield front view
  • 3-1000 kva 34.5 kv to 0.48 kv three-phase five-column bess transformer side instrument box with grounding shield right front 45 degree
  • 4-1000 kva 34.5 kv to 0.48 kv three-phase five-column bess transformer side instrument box with grounding shield right side view
  • 5-1000 kva 34.5 kv to 0.48 kv three-phase five-column bess transformer side instrument box with grounding shield right rear 45 degree
  • 6-1000 kva 34.5 kv to 0.48 kv three-phase five-column bess transformer side instrument box with grounding shield rear view
  • 7-1000 kva 34.5 kv to 0.48 kv three-phase five-column bess transformer side instrument box with grounding shield left rear 45 degree
  • 8-1000 kva 34.5 kv to 0.48 kv three-phase five-column bess transformer side instrument box with grounding shield left side view
  • 9-1000 kva 34.5 kv to 0.48 kv three-phase five-column bess transformer side instrument box with grounding shield left front 45 degree
  • 1-1000 kva 34.5 kv to 0.48 kv three-phase five-column bess transformer side instrument box with grounding shield internal view with enclosure open
  • 2-1000 kva 34.5 kv to 0.48 kv three-phase five-column bess transformer side instrument box with grounding shield front view
  • 3-1000 kva 34.5 kv to 0.48 kv three-phase five-column bess transformer side instrument box with grounding shield right front 45 degree
  • 4-1000 kva 34.5 kv to 0.48 kv three-phase five-column bess transformer side instrument box with grounding shield right side view
  • 5-1000 kva 34.5 kv to 0.48 kv three-phase five-column bess transformer side instrument box with grounding shield right rear 45 degree
  • 6-1000 kva 34.5 kv to 0.48 kv three-phase five-column bess transformer side instrument box with grounding shield rear view
  • 7-1000 kva 34.5 kv to 0.48 kv three-phase five-column bess transformer side instrument box with grounding shield left rear 45 degree
  • 8-1000 kva 34.5 kv to 0.48 kv three-phase five-column bess transformer side instrument box with grounding shield left side view
  • 9-1000 kva 34.5 kv to 0.48 kv three-phase five-column bess transformer side instrument box with grounding shield left front 45 degree

1000 KVA Bess Transformer -34.5/0.48 KV | USA 2026

Delivery Country: America 2025
Capacity: 2500kVA
Voltage: 34.5/0.48 kV
Feature: DOE Efficiency

1000 kva 34.5 kv to 0.48 kv three-phase five-column bess transformer side instrument box with grounding shield

2500 kVA BESS Pad-Mounted Transformer for America, 34.5/0.48 kV, with DOE High Efficiency

01 General

1.1 Project Description

In 2026, a U.S. energy infrastructure contractor ordered a 1000 kVA pad mounted transformer for BESS system applications as part of a community battery energy storage project connected to a 34.5 kV underground utility distribution network. Although the transformer nameplate follows conventional pad-mounted transformer voltage labeling, the unit was specifically engineered and operated as a BESS step up pad mounted transformer for utility-scale underground grid interconnection.

In this BESS application, power enters the BESS transformer from the 0.48 kV low-voltage side through the battery inverter system and is stepped up to 34.5 kV for connection to the underground loop-feed utility network. This low-voltage input and high-voltage output configuration enables stable energy export from the battery energy storage system to the local utility grid.

To satisfy the operational requirements of modern energy storage infrastructure, the BESS transformer integrates FR3 insulating fluid, a three-phase five-leg core structure, DOE high-efficiency performance up to 99.43%, and a 5.32% impedance design for stable inverter-connected operation. Additional configurations of the pad mounted transformer for BESS system include static shielding, lightning protection, side-mounted gauge box, terminal box, monitoring instruments with alarm contacts, and a powder-coated white enclosure (RAL 9003), supporting safe outdoor operation, remote monitoring capability, and improved thermal performance in utility-scale BESS installations.

1.2 Technical Specification

1000 kVA underground distribution transformer specification and data sheet

Delivered toAmerica
Year2026
TypeThree phase pad mount transformer
StandardIEEE Std C57.12.34-2022
Rated Power1000KVA
Frequency60HZ
FeedLoop
FrontDead
Phasethree
Cooling TypeKNAN
Liquid insulantFR3 Oil
Primary Voltage34.5 kV
Secondary Voltage0.48 kV
Vector GroupYNyn0
Winding MaterialAluminum
Impedance5.32%
Efficiency and Losses StandardDOE Efficiency  99.43%
Tap ChangerNLTC
Tapping Range±2*2.5%
No Load Loss1.3 kW
On Load Loss6.94 kW
Accessoriesside instrument box

1.3 Drawings

1000 kVA underground distribution transformer drawing and nameplate

02 Manufacturing

2.1 Three-Phase Five-Leg Core

The BESS transformer adopts a three-phase five-limb core structure designed to improve magnetic flux balance, reduce zero-sequence effects, and enhance operational stability under inverter-based energy storage loading conditions. The core design supports DOE high-efficiency performance up to 99.43%, helping the transformer maintain stable long-term operation in battery energy storage system applications.

 

 

1000 kva, 34.5 kv to 0.48 kv three‑phase five‑column bess transformer iron core with workers inserting iron yoke

2.2 Low-Loss Winding

The BESS step up pad mount transformer uses aluminum windings designed for 34.5 kV / 0.48 kV YNyn0 operation with 5.32% impedance configuration, providing stable voltage transformation between the battery inverter system and the utility grid interface. The winding structure is optimized for thermal reliability and continuous cycling operation in BESS applications.

2.3 Static Shield

The sealed pad-mounted tank structure of the pad mounted transformer for BESS system is designed for FR3 insulating fluid and integrates static shielding to improve insulation stability and reduce electrical interference associated with inverter-based energy storage systems. The enclosure adopts a powder-coated white finish (RAL 9003) to improve outdoor durability and thermal performance in utility-scale BESS installations.

 

1000 kva 34.5 kv to 0.48 kv three-phase five-column bess transformer in the workshop

2.4 Terminal Box

The pad mounted transformer for BESS system integrates both a dedicated terminal box and a side-mounted gauge box to support organized signal wiring, monitoring integration, and maintenance accessibility. This configuration improves field installation efficiency and simplifies operational management for BESS step up pad mount transformer applications in utility-scale energy storage projects.

2.5 Monitoring Instruments with Alarm Contacts

To support unattended operation and remote monitoring, the BESS transformer is equipped with a top oil thermometer, an oil level gauge, and vacuum pressure gauge with alarm contacts. These monitoring devices allow operating signals and abnormal conditions to be transmitted directly to SCADA or BESS control systems, improving operational visibility and protection coordination in energy storage applications.

03 Testing

Testing Standard

1000 kva 34.5 kv to 0.48 kv three-phase five-column bess transformer Testing Standard

Testing Results

1000 kva 34.5 kv to 0.48 kv three-phase five-column bess transformer Test Results-1 1000 kva 34.5 kv to 0.48 kv three-phase five-column bess transformer Test Results-2

04 Packing and Shipping

Let's Discuss Your Needs and Find the Right Solution!

Lorem ipsum dolor sit amet, sea ea saepe intellegam, purto utinam consetetur ex duo, an recteque liberavisse signiferumque qui. An sea duis dissentiunt.
Scroll to Top