x
Send Your Inquiry Today
Quick Quote
  • 50 kva 2.4kv 7.2kv dual primary to 0.12kv 0.24kv dual secondary electrical pole transformer front view
  • 50 kva 2.4kv 7.2kv dual primary to 0.12kv 0.24kv dual secondary electrical pole transformer right side view
  • 50 kva 2.4kv 7.2kv dual primary to 0.12kv 0.24kv dual secondary electrical pole transformer right rear 45deg view
  • 50 kva 2.4kv 7.2kv dual primary to 0.12kv 0.24kv dual secondary electrical pole transformer rear view
  • 50 kva 2.4kv 7.2kv dual primary to 0.12kv 0.24kv dual secondary electrical pole transformer left rear 45deg view
  • 50 kva 2.4kv 7.2kv dual primary to 0.12kv 0.24kv dual secondary electrical pole transformer top view
  • 50 kva 2.4kv 7.2kv dual primary to 0.12kv 0.24kv dual secondary electrical pole transformer front view
  • 50 kva 2.4kv 7.2kv dual primary to 0.12kv 0.24kv dual secondary electrical pole transformer right side view
  • 50 kva 2.4kv 7.2kv dual primary to 0.12kv 0.24kv dual secondary electrical pole transformer right rear 45deg view
  • 50 kva 2.4kv 7.2kv dual primary to 0.12kv 0.24kv dual secondary electrical pole transformer rear view
  • 50 kva 2.4kv 7.2kv dual primary to 0.12kv 0.24kv dual secondary electrical pole transformer left rear 45deg view
  • 50 kva 2.4kv 7.2kv dual primary to 0.12kv 0.24kv dual secondary electrical pole transformer top view

50 KVA Electrical Transformer On Pole-2.4*7.2/0.12*0.24 KV | Canada 2025

Delivery Country: Canada 2025
Capacity: 50kVA
Voltage: 2.4*7.2-0.12/0.24kV
Feature: Dual-voltage transformer with IFD

50 kva 2.4kv 7.2kv dual primary to 0.12kv 0.24kv dual secondary electrical pole transformer

50 kVA electrical transformer on pole - dual-voltage with IFD for reliable Canadian rural distribution

01 General

1.1 Customer Pain Points

Canadian distribution networks typically require 120/240 V secondary output, while operating across multiple primary voltage structures, particularly in rural and low-density regions. Utilities are therefore under pressure to deploy electrical pole transformer transformers that can adapt to different feeder configurations without increasing complexity.

Key challenges include:
• Limited access in rural areas, requiring high reliability and minimal maintenance
• Increased focus on operational safety, especially internal fault protection
• Inventory and logistics pressure caused by single-voltage transformer designs
Traditional solutions often lack the flexibility needed to address these challenges, making a dual-voltage pole-mounted transformer with integrated IFD protection a more efficient and safer alternative.

1.2 Canadian Overhead Distribution Networks

This 50kVA Pole-mounted electrical transformer is designed for overhead distribution systems supplying 120/240 V service in Canada. Its configuration makes it particularly suitable for:
• Rural overhead feeder lines
• Residential communities and light commercial loads
• Utility distribution networks requiring CSA C2.2-06 compliance
The dual-voltage primary design enables deployment across different network sections without structural changes, enhancing system flexibility while maintaining consistent performance under outdoor operating conditions.

1.3 Product Advantages

This pole-mounted electrical transformer delivers a balanced combination of flexibility, safety, and energy efficiency through the following advantages:

  • Dual-voltage primary configuration
    Reduces on-site replacement requirements and simplifies inventory management.
  • Integrated Internal Fuse Device (IFD)
    Provides enhanced internal fault protection, improving operational safety and reducing risk to surrounding equipment.
  • High energy efficiency
    Efficiency of ≥98.83% helps lower long-term operating costs.
  • Optimized low-loss design
    • No-load loss: 139 W
    • Load loss: 693 W
      Ensures stable thermal performance and reliable long-term operation.

Combined with ONAN cooling and a robust pole-mounted design, this solution meets the practical demands of Canadian overhead distribution networks.

1.4 Technical Specification

50kVA electrical transformer on pole specification and data sheet

Delivered toCanada
Year2025
TypePole mounted transformer
StandardCSA C2.2-06
Rated Power50KVA
Frequency60HZ
PhaseSingle
Cooling TypeONAN
Liquid insulantMineral Oil
Primary Voltage2.4*7.2-0.12/0.24kV
Secondary Voltage120 / 240 V
PolarityAdditive
Vector GroupIi6
Winding MaterialAluminum
Impedance2.85%(±10%)
Efficiency≥98.83%
Tap ChangerNLTC
No Load Loss139 W
On Load Loss693 W
AccessoriesDual-voltage transformer with IFD

1.5 Drawings

50kVA electrical transformer on pole dimensions and weight details

 

02 Manufacturing

2.1 Core

Coil setup: LV foil, HV wire, mix of copper and aluminum. Foil spreads current, sheds heat. Wire bends, stays insulated. Copper-aluminum blend hits efficiency and cost right. Durable. Works in urban streets, rural lines, whatever the day throws at it. Reliable, steady, doing its job without fuss.

50 kva 2.4kv 7.2kv dual primary to 0.12kv 0.24kv dual secondary electrical pole transformer windings

2.2 9kV HV Arrester

50 kva 2.4kv 7.2kv dual primary to 0.12kv 0.24kv dual secondary electrical pole transformer 9kV HV arresterA 9kV high voltage arrester is installed to protect the transformer from lightning surges and transient overvoltage events common in overhead distribution systems. By limiting surge voltage before it reaches internal insulation, the arrester reduces electrical stress on critical components and improves overall transformer durability in rural network applications.

2.3 Internal Fuse Device (IFD)

The Internal Fuse Device (IFD) is designed to disconnect the transformer internally during severe fault conditions. This protection mechanism reduces the risk of tank rupture, limits fault impact, and enhances personnel and system safety. The integrated IFD complies with utility safety requirements for pole-mounted transformers in Canadian distribution networks.50 kva 2.4kv 7.2kv dual primary to 0.12kv 0.24kv dual secondary electrical pole transformer ifd

2.4 50 kVA Electrical Pole Transformer Details

2.5 Final Assembly

At the final assembly stage, the transformer’s active parts are fully completed, with the core and windings securely assembled and all internal leads precisely welded and connected. Switching components are installed and fixed in position, forming a finished transformer core assembly.50 kva 2.4kv 7.2kv dual primary to 0.12kv 0.24kv dual secondary electrical pole transformer active parts

03 FAQ

Q1: How is the dual-voltage primary configuration selected or changed?

A: The transformer is equipped with a dual-voltage primary design, allowing voltage selection through predefined internal connections during installation or commissioning.

 

Q2: Is this transformer suitable for long rural feeder lines?

A: Yes. With optimized impedance (2.85% ±10%) and high efficiency, the transformer performs reliably on long rural overhead distribution lines.

 

Q3: Can the transformer be customized for specific utility requirements?